Viking
Power Load Monitors
Design Features
The Viking
Power load monitors provide a simple, cost effective,
state-of-the-art method to monitor pump and system problems and
alarm or shut down the pump when a change of load is detected at
the motor. They are applicable to positive displacement or
centrifugal pumps, as well as other types of motor-driven
equipment. They are especially useful for pumps which are
susceptible to damage due to dry running, such as sealless
magnetic drive pumps.
The M-10
monitors can be set to detect either an underload condition
(indicating dry running or cavitation) or an overload condition
(indicating overpressure* situations). The M-20 can detect
both underload and overload conditions. The monitors are
capable of handling both 50 and 60 Hz power, single or three
phase, on loads up to 999 HP.
*Note: The
power load monitor should not be used as exclusive protection in
case of sudden discharge line blockage on positive displacement
pumps. Other means of protection such as a pressure relief
valve must be used in conjunction with the power load monitor to
avoid pressure spikes in the system.
Specifications
- Supply
Voltage:
M10: 1-phase 100-240, 3-phase 100-600; M20:1-phase 100-240,
3-phase 100-240, 380-500, 525-600.
- Mounting:
35mm
DIN-rail 46277
- Approved
to:
UL, CE (up to 690V), cUL
- Startup
Delay:
M-10: 1-64 seconds; M-20: 1-999 seconds
- Response
Delay:
M10:
0.05-64 seconds; M-20: 0.1-90 seconds
Products
Note: Price
& availability are subject to change without notice.
|